Methyl Cyclopentane Chemical Storage Specifications

Compliant storage and rental solutions for Methyl Cyclopentane (C6H12O2). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Methyl Cyclopentane

Methyl Cyclopentane is a colorless liquid with a sweet odor. It is used as a solvent and to make other chemicals. * Methyl Cyclopentane is on the Hazardous Substance List because it is cited by DOT and NFPA. * This chemical is on the Special Health Hazard Substance List because it is FLAMMABLE.

Structured hazard data

Hazard class
See SDS
Storage category
Flammable Storage
Flammable
Yes
Flash point
<-10 °C at 1,013 hPa.
Storage temperature
Ambient
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Oxidizers

2.6 flammable liquid 2 Flam. Liq. 2 H225 3.2 skin corrosion/irritation 2 Skin Irrit. 2 H315 3.8D specific target organ toxicity - single exposure (narcotic effects, drowsiness) 3 STOT SE 3 H336 3.10 aspiration hazard 1 Asp. Tox. 1 H304

Fire Suppression System

Dry Chemical fire suppression is recommended for Methyl Cyclopentane

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Methyl cyclopentane (C6H12O2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Methyl cyclopentane should account for its listed hazards, climate control needs (Ambient), and segregation requirements. Oxidizers

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Melting point/freezing point -142 °C at 1,013 hPa Initial boiling point and boiling range 72 °C at 1,013 hPa Flash point <-10 °C at 1,013 hPa. Colorless Liquid

Matched to this chemical

Recommended storage solutions for Methyl Cyclopentane

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Methyl cyclopentane be stored?

Store Methyl cyclopentane in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: Ambient. Compatibility notes: Oxidizers US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Methyl cyclopentane flammable?

Yes — Methyl cyclopentane is flagged as a flammable hazard in this database (Yes). Flash point: <-10 °C at 1,013 hPa.. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Methyl cyclopentane?

Methyl cyclopentane is listed as: Consult the SDS and applicable hazard classification. 2.6 flammable liquid 2 Flam. Liq. 2 H225 3.2 skin corrosion/irritation 2 Skin Irrit. 2 H315 3.8D specific target organ toxicity - single exposure (narcotic effects, drowsiness) 3 STOT SE 3 H336 3.10 aspiration hazard 1 Asp. Tox. 1 H304

What fire suppression is recommended for Methyl cyclopentane?

Dry Chemical fire suppression is generally recommended for Methyl cyclopentane (C6H12O2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Methyl cyclopentane storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Methyl cyclopentane. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.